Match electricity factors to the question being answered
Distinguish average accounting, marginal response, time weighting, and gas-scope conventions.
On this page
The question for today
What you’ll understand
- Compute an energy-weighted emissions account with compatible factor units.
- Distinguish annual average, modeled hourly, and marginal factors.
- State geographical, temporal, gas, and procurement-accounting assumptions.
Multiplying electricity by an emissions factor looks simple because the difficult assumptions sit inside the factor. A regional annual generation average, an hourly modeled value, and a marginal response estimate describe different questions. Their numerical units can match while their meanings do not. State whether the calculation allocates an inventory or predicts an intervention’s consequences, then select compatible factors and energy boundaries. All grid factors used in this lesson’s calculations are fictional fixtures, not current regional estimates.
Account for the electricity at the right granularity
An average factor allocates a generation or consumption emissions account across electricity units for its stated region and period. EPA eGRID provides emissions and generation information for US electricity accounting, including annual data. An annual average cannot reveal the hour-to-hour pattern of one specific future job. Check whether imports, exports, transmission losses, or upstream lifecycle stages are included instead of silently attaching a generation-only factor to a broader consumption claim.
Time-resolved accounting multiplies each interval’s electricity by the corresponding factor before summing. An arithmetic average of hourly factors gives each hour equal weight, whereas the workload may use unequal electricity across hours. Weight by energy when reporting an aggregate factor for that workload. Ensure that energy already includes any intended facility allocation; multiplying facility-inclusive electricity by PUE again changes the boundary and counts supporting consumption twice.
Marginal models answer a different conditional question
A marginal factor models how emissions change when electricity demand changes under specified conditions. Short-run dispatch response and long-run capacity response are different models and horizons. NREL’s Cambium Version 2021 documentation describes modeled future scenarios and relevant average and marginal metrics; those modeled values should not be presented as direct measurements of today’s real-time grid. The selected scenario, year, geography, and response horizon are part of the result, not optional metadata.
A linear marginal calculation can be useful for a sufficiently scoped demand change under the model’s assumptions. It is not a guarantee that arbitrarily large coordinated shifts preserve the same factors. Capacity, congestion, forecast error, and other workloads can change the response. Report a scenario-dependent predicted difference separately from an average inventory difference. Agreement is possible, but numerical disagreement does not indicate an arithmetic mistake when the estimands differ.
Declare gas and procurement conventions
Carbon dioxide and carbon-dioxide-equivalent are not interchangeable labels. A CO2e account needs a stated set of gases and conversion convention, including the global-warming-potential horizon where relevant. Unit conversion from grams to kilograms cannot repair a mismatch in gases or lifecycle coverage. Keep the original factor metadata and publish the version used so the calculation can be repeated even if a dataset later receives a revision.
GHG Protocol Scope 2 guidance distinguishes location-based and market-based electricity accounting. Contractual procurement information and physical grid response need not answer the same question. A market-based accounting reduction therefore should not be relabeled as proven avoided marginal emissions without a separate argument. For engineering decisions, show the chosen accounting method, the modeled alternative if used, and sensitivity to factor uncertainty. This makes assumptions inspectable without pretending that one scalar captures every environmental consequence.
Work it through
Energy weighting and intervention modeling produce distinct totals
A fictional workload uses 2 kWh in hour 1 and 1 kWh in hour 2. Average factors are 400 and 100 g CO2e/kWh. Separately, stipulated marginal factors for a small shift are 500 and 300 g CO2e/kWh. Compute its account and the modeled change from moving 1 kWh from hour 1 to hour 2.
The average inventory is 2×400+1×100=900 g CO2e. Its energy-weighted factor is 900/3=300 g/kWh. The unweighted hourly average, 250 g/kWh, would incorrectly give 750 g for this unequal load profile.
After shifting 1 kWh, energy is 1 kWh and 2 kWh across the two hours. Average accounting becomes 1×400+2×100=600 g, an accounting difference of −300 g under these fictional average factors.
The separate marginal model gives (−1)×500+(+1)×300=−200 g. Its modeled reduction differs from the 300 g inventory change because the factors answer different questions under different assumptions.
The original account is 900 g CO2e. The shift changes average accounting by −300 g and the stipulated marginal prediction by −200 g; neither fixture describes a current grid.
The living notebook
Explore the model
Interactive lab · function
Duration weighting changes a time average
Reset, set Coefficient a to 1 and Position x to 1; predict area 1/3 and manually divide by duration 1 to get average height 1/3 before Step. Reset, set a to 1 and x to 2; predict area 8/3 and average height 4/3 before Step. This dimensionless nonnegative quadratic illustrates interval weighting only; it contains no electricity profile, emissions dataset, or marginal grid model.
- y at chosen x
- 0.608
- Tangent slope · 2ax
- 1.35
- Signed area · ax³/3
- 0.182
This lab uses only y = ax². Playback traces the curve within the fixed integration interval from 0 to x; it does not estimate numerical error or change the chosen point. Parameter changes pause playback and recompute the model at the current elapsed time. Reset restores both parameters and returns time to zero. Playback starts paused. Adjust either parameter, then choose Play or Step.
Look forAn average must state its weighting and interval; its name alone does not define them.
Pause & reason
Check your understanding
Your turn
Try it yourself
A fictional facility-inclusive interval uses 0.5 kWh with a factor of 200 g CO2e/kWh. Express its account in grams and kilograms. Recompute with the identical factor written as 0.2 kg CO2e/kWh.
Take a moment to make a prediction or work it out on paper. Open a hint when you need one.
Give me a hint
Preserve the factor’s gas scope and divide grams by 1000 to obtain kilograms.
Compare with the solution
The account is 0.5×200=100 g CO2e=0.1 kg CO2e. Using kilograms directly gives 0.5×0.2=0.1 kg CO2e. These are identical unit representations of the same stipulated average account. The calculation alone does not establish marginal avoidance or include a lifecycle stage absent from the factor.
Keep the idea
Take it with you
- Specify time, geography, gas scope, lifecycle coverage, and factor version.
- Weight interval factors by interval energy when forming a workload average.
- Average accounting and marginal impact models require separate interpretations.
Read further
Original sources and deeper explanations to follow at your own pace.
Optional progress, saved in this browser when available. Revisit any lesson at any time.
Lesson not marked complete.