research28 min studyLesson 871 in Physics

Distance measures and distance duality

Translate angles, fluxes, and redshifts into explicitly defined FLRW distances, then test the assumptions behind reciprocity.

On this page

What you’ll understand

  • Distinguish comoving, angular-diameter, and luminosity distances.
  • Derive the two redshift factors in bolometric flux.
  • Separate a duality test from opacity and calibration assumptions.

An expanding universe does not provide one distance that can be substituted into every observational formula. An angle compares a source’s proper transverse size with an angular-diameter distance, while a bolometric flux defines a luminosity distance. Both involve events on our past light cone. Confusing these conventions produces errors that grow with redshift even when the underlying cosmology is correct. We will declare a homogeneous background, derive its distance relations, and identify the additional physical assumptions required when comparing brightness and angular size.

Start with a metric and a distance convention

Assume a spatially flat Friedmann–Lemaître–Robertson–Walker background with present scale factor one. Redshift from expansion obeys one plus z equal to inverse emission scale factor. Let H be the expansion rate and retain the speed of light c explicitly. Integrating a radial null ray gives the line-of-sight comoving distance chi. In this flat case chi also equals transverse comoving distance D M; spatial curvature would change that last identification.

The angular-diameter distance D A converts an observed small angle in radians into a proper transverse size at emission. A comoving ruler must first be divided by one plus redshift before using that definition. Luminosity distance D L is instead defined by a bolometric inverse-square flux law. Neither is generally equal to lookback time multiplied by c. Peculiar velocities and gravitational shifts also contribute to measured redshifts and require separate treatment when estimating the background relation.

χ(z)=c∫0zdz′H(z′),DM=χ(Ωk=0),DA=DM1+z,F=L4πDL2\chi(z)=c\int_0^z\frac{dz'}{H(z')},\qquad D_M=\chi\quad(\Omega_k=0),\qquad D_A=\frac{D_M}{1+z},\qquad F=\frac{L}{4\pi D_L^2}
H has inverse-time units, chi and the distances have length units, L is emitted bolometric power, and F is observed power per area. The equality between chi and D M assumes spatial flatness.↔ Scroll wide equations horizontally.

Account for photon energy and arrival time

A photon loses an energy factor one plus redshift between emission and observation. The arrival interval for successive wave packets is also longer by that factor. At the observer the radiation is distributed over a sphere with area determined by the transverse comoving distance, since the present scale factor is one. Combining energy loss and arrival-time dilation gives two factors in flux, and hence one factor between luminosity and transverse comoving distances.

Distance duality then relates luminosity and angular-diameter distances with two powers of one plus redshift. More generally reciprocity holds for metric light propagation along null geodesics, with photon conservation needed for its brightness interpretation. It does not require choosing numerical matter or dark-energy densities. Absorption, photon conversion, inconsistent source definitions, or calibration errors can make observational estimates fail the relation without demonstrating a failure of the background metric itself.

DL=(1+z)DM=(1+z)2DA,η(z)≡DL(1+z)2DA=1,IobsIem=(1+z)−4D_L=(1+z)D_M=(1+z)^2D_A,\qquad \eta(z)\equiv\frac{D_L}{(1+z)^2D_A}=1,\qquad \frac{I_{\mathrm{obs}}}{I_{\mathrm{em}}}=(1+z)^{-4}
The final equation is bolometric surface-brightness dimming for otherwise matched resolved source patches with conserved photons. Intrinsic evolution and finite-band spectral corrections must be controlled in an observational comparison.↔ Scroll wide equations horizontally.

A consistency test needs matched observables

A telescope measures flux through finite passbands rather than integrating every photon frequency. Comparing an observed passband to an emitted rest-frame luminosity therefore requires a spectral correction and a convention for extinction. Galaxy sizes also evolve, so an apparent angular size is not automatically a calibrated standard ruler. A useful duality analysis must propagate these source and instrument uncertainties, including correlations when the same observations enter both inferred distance estimates.

Consider uniform attenuation with optical depth tau. Flux is multiplied by its exponential suppression, while a distance inferred by assuming transparent propagation increases by the exponential of half tau. The geometric angular-diameter distance need not change. This example shows why the definition of an inferred distance matters: a flux deficit can be expressed as an anomalous brightness distance, but it does not by itself determine whether the cause is absorption, evolution, selection, or exotic photon physics.

One redshift, three distances

A synthetic flat-background calculation gives D M = 3000 Mpc at z = 1. A source has proper transverse size 15 kpc and known bolometric luminosity L. Find D A, D L, its angular size, and the ratio of its true flux to the flux obtained by incorrectly putting D A into the luminosity-distance formula.

  1. Divide the transverse comoving distance by two: DA=1500 MpcD_A=1500\,\mathrm{Mpc}. Multiply it by two instead for DL=6000 MpcD_L=6000\,\mathrm{Mpc}. These relations do not require estimating a velocity from z.

  2. Convert the source size to 0.015 Mpc. Its angle is 0.015/1500=10−50.015/1500=10^{-5} radians, using proper size with angular-diameter distance.

  3. With L held fixed the flux ratio is (DA/DL)2=(1/4)2=1/16(D_A/D_L)^2=(1/4)^2=1/16. Substituting the angular-diameter distance would overpredict the flux by sixteen.

The result

The distances are 1500 and 6000 Mpc, the angle is ten microradians, and the true flux is one sixteenth of that incorrect prediction.

Explore the model

Interactive lab

Interactive lab · function

Track the squared distance factor

Interpret the plotted value as a squared distance factor, whose reciprocal would scale flux. Reset, set Coefficient a = 1 and Position x = 1, and predict y = 1. For a fresh comparison Reset, set a = 1 and x = 2, and predict y = 4 and an inverse factor of one quarter.

Track the squared distance factorThis lab uses only y = ax². Playback traces the curve within the fixed integration interval from 0 to x; it does not estimate numerical error or change the chosen point. Current readings: y at chosen x: 0.608; Tangent slope · 2ax: 1.35; Signed area · ax³/3: 0.182. All parameters are adjustable with the labeled controls below.−2.4−1.201.22.4−9−4.504.59xy(x, ax²)
y = ax²TangentSigned integral
y at chosen x
0.608
Tangent slope · 2ax
1.35
Signed area · ax³/3
0.182
t = 0 s

This lab uses only y = ax². Playback traces the curve within the fixed integration interval from 0 to x; it does not estimate numerical error or change the chosen point. Parameter changes pause playback and recompute the model at the current elapsed time. Reset restores both parameters and returns time to zero. Playback starts paused. Adjust either parameter, then choose Play or Step.

Look forThe lab plots a parabola, not cosmological distances or photon transport. Its value is the denominator factor in this analogy, not the flux itself.

Check your understanding

At fixed redshift, what additional assumption is required to infer luminosity distance from geometric reciprocity using measured brightness?

Try it yourself

At z = 0.5 a synthetic source has geometric D A = 1200 Mpc. Find D M and D L. Suppose uniform attenuation reduces its bolometric flux to one quarter of the transparent value, while its calibrated angular size is unchanged. What luminosity distance and eta would a transparent-flux analysis infer?

Take a moment to make a prediction or work it out on paper. Open a hint when you need one.

Give me a hint

A factor of four in inverse-square flux corresponds to a factor of two in the inferred distance.

Compare with the solution

The geometric values are DM=1.5(1200)=1800 MpcD_M=1.5(1200)=1800\,\mathrm{Mpc} and DL=1.52(1200)=2700 MpcD_L=1.5^2(1200)=2700\,\mathrm{Mpc}. Quarter flux gives an inferred luminosity distance of 5400 Mpc. Therefore η=5400/[1.52(1200)]=2\eta=5400/[1.5^2(1200)]=2. The mismatch was generated by the stated attenuation, so it is not evidence here for altered geometric reciprocity.

Take it with you

  • Use proper sizes with D A and bolometric luminosities with D L.
  • Two redshift effects connect luminosity and transverse comoving distances.
  • A brightness-distance consistency test must control photon loss, source evolution, and calibration.

Read further

Original sources and deeper explanations to follow at your own pace.

Optional progress, saved in this browser when available. Revisit any lesson at any time.

Lesson not marked complete.